IBM 360/30 (1965)

system control panel after my 360/30
Power off

Try it

  1. POWER ON: the console runs a short lamp check, then waits in manual state (MAN lamp).
  2. LAMP TEST lights every indicator.
  3. Set the LOAD UNIT dials G H J (for example 00C, a card reader) and press LOAD: the system reads the IPL record through channel one, loads the PSW and starts (SYSTEM lamp).
  4. STOP, then turn RATE to INSN STEP and press START to step.
  5. Set an address on dials A–D and press DISPLAY: the main storage data register shows the byte; dials H J and STORE write one.

Click a dial to turn it forward, Shift-click to turn it back. The EMERGENCY PULL cuts all power; the two usage meters run in real time while the system works (last digit: tenths of an hour), the key switches to the customer engineer meter.

What you see

On the Model 30 the indicators are lamps behind printed label strips: a bit is on when its label lights up. The upper panel shows the read-only storage (microprogram) control word, the count register and channel one; the lower panel channel two, the multiplexer channel, the main storage address and data registers, the ALU output and the A and B registers.

An illustration, not an emulator of the 2030 microcode: the lamps follow a simplified model of storage access, IPL and a running program. Button labels that are not legible on my console are left blank.

Specs

ShippedJune 1965 (announced April 1964)
Main storage8–64 KB
Data path1 byte, microprogrammed
Console257 indicator lamps behind label strips plus 5 status lamps, 8 hex dials and a display/store selector, 4 rotary switches, 16 push buttons, 2 usage meters